Place of use
These cables are used as main line cable in CATV and CCTV systems where low attenuation and high frequency transmittance is desired. This type of cables is halogen-free, has flame-retarder and low smoke density.
Inner Conductor | 1,63 mmØ Electrolytic Solid Copper |
Insulation | 7,15 Ø Physical Foam PE |
1.Screen | 100 % Coverage Cu-Pes Tape |
2.Screen | Electrolytic Copper Braid, %55 coverage |
Outer Sheath | 10,20 Ø HFFR Compound, RAL 7001 Grey |
Product Code | Dimension and Weights | Electrical Properties | |||||||||
Nominal Cross Section | Overall Diemeter ( ~ ) |
Net Weight ( ~ ) |
Standart Lenght | Max. Dc Conductor Resistance at 20◦ C | Current Carrying Capacity | ||||||
In Ground at 20° C | On Air at 30° C |
INSULATION RESISTANCE | MUTUAL CAPACITANCE | VELOCITY OF PROPAGATION | OPERATING VOLTAGE | TEST VOLTAGE | BENDING RADIUS | TEMPERATURE RANGE | IMPEDANCE |
MΩxkm >2000 | 53±2 pF/mt | 82 % | 2 kV | 5 kV | 20x D mm | -40ºC+70ºC | 75±3 Ω |
FLAME RETARDANT TEST | SMOKE DENSITY TEST | TEST ON CORROSIVENESS OF COMBUSTION GASES | HALOGEN FREE TEST | FLAME PROPOGATION TEST |
EC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 | IEC 61034-2 VDE 0482-1034-2 EN 61034-2 | IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3 | IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1 | IEC 60332-3-25 VDE 0482-332-3-25 EN 60332-3-25 |